Accuflo™ Metering Valve
1/2" Orifice, Multi-turn
 |
| • |
All wetted components are constructed of high purity fluoropolymers for ultrapure and corrosion resistant performance. |
| • |
Five full turn manual adjustment range enables you to precisely control media flow. |
| • |
Standard panel mount configuration. |
|
You have the ability to access 3D and 2D product data that is compatible with today's CAD modeling packages. To decrease system design time, simply download parts directly into your design.
|
 Click to enlarge |
Panel Mounting Hole
 Click to enlarge
Panel Mount Instructions - Panel thickness must be within 0.10" (2.5 mm) to 0.25" (6.4 mm). To panel mount, the handle must be removed. Remove the screw holding the handle in place. Remove the handle. To install valve, remove the panel mount nut and insert valve into the panel. Thread the panel mount nut onto the valve and tighten nut to 40 inch•lbs (4.5N•m) torque, or 1/8-turn beyond hand tight. Reinstall handle. Be careful not to over tighten handle screw. |
| Maximum continuous use pressure: |
100 PSIG (689 kPa) @ 73°F (23°C) media temperature |
Peak pressure for short durations (proof pressure for less than 24 hours): |
150 PSIG (1034 kPa) @ 73°F (23°C) media temperature |
| Maximum continuous use temperature: |
300° F (149°C) at media pressures up to 50 PSIG (345 kPa) |
| Actuation cycle life: |
5,000 Cycles |
| Materials: |
All wetted parts are PFA and PTFE. Nonwetted parts are Viton®, PVDF and PTFE-filled PVDF. |
|
|